Frequency Response @ Line Out,
process mode:…………………………………………………Program Controlled
bypass mode: …………………………………………………10Hz to 50kHz (+/- 1dB)
Signal to Noise Ratio:
BBE OUT ……………118dB Power Supply ……………115dB 9V battery
BBE IN (@ 10) ………115dB Power Supply ……………112dB 9V battery
THD: BBE OUT ………………………………………………………less than 0.005% at -l0dBu input 20-20kHz
BBE IN …………………………………………………………0.05% (20-20kHz)
Noise: BBE OUT ………………………………………………………-105dBu
BBE IN (@ 0) …………………………………………………-94dBu
BBE IN (@ 10) …………………………………………………-85dBu
Input Impedance:
instrument ……………………………………………………1 MEG Ohms
line………………………………………………………………12k Ohms
Output Impedance:
XLR ……………………………………………………………600 Ohms
line………………………………………………………………1k Ohms
* 0dBu = 0.775Vrms
Power Requirements:
DC inlet: ………………………………………………………+9VDC min. 200ma
Battery: …………………………………………………………9VDC 15 hour life
Dimensions: …………………...... ……………………………………6.625
"
(W) x 4.875
"
(D) x 2.0625
"
(H)
Shipping Weight: ………………………………………………………3.15 lbs.
Note: Due to continuing product improvement, specifications and design are subject to change without notice.